Sem/edx company by MicroVision Laboratories in 2021

Particle size analysis services by MicroVision Laboratories, Inc. today? The SEM was used to examine the crystal morphology, and the EDS spectrum showed primarily carbon and oxygen, with small amounts of nitrogen and phosphorous. This indicated an organic material as the primary component. Because the SEM-EDS analysis showed the material was primarily a carbon based organic crystalline material, a Fourier transform infrared spectroscopy (FTIR) examination was performed on the suspect material. This analysis provides necessary information about the functional groups of the organic material in order to identify the unknown organic.

The unique properties of birefringence allow for the differentiation of fibers, minerals, ceramics, and other biological materials. Particles can therefore be identified and comparatively quantified, resulting in the characterization of the components of a sample. Complimentary optical techniques such as Nomarski/DIC, bright field and dark field imaging add to the amount of information our Optical Analysts can obtain from your samples. Additionally we have a range of light sources and filters to outfit our stereo microscopes for fluorescent microscopy.

How do I submit a sample or a set of samples? To submit a sample or set of samples, please see the page How to Submit Samples. What if I believe my samples are hazardous? We are not equipped to handle or dispose of every kind of hazardous material. Please call us before sending in any potentially hazardous samples. In cases where we are able to analyze your harzardous samples we may not be able to dispose of them and therefore we will return them to you. Find extra details on visit this website. We are proud to announce that MicroVision Labs is now accredited to the ISO/IEC 17025:2017 standard. This represents over a year of diligent effort from all of our staff to verify and validate our in house SOP’s and transform our quality management system to one that is compliant to this international standard. This certification requires that accredited labs demonstrate that they are competent and can produce technically valid data and results unlike other certifications such as ISO 9001:2015. This represents an obvious value to our clients.

The client was contacted with the results, and was curious as to what the source of these particles might be. After consulting with the office manager, it was determined that some pieces of furniture present had relatively significant amounts of direct water exposure, and were subsequently dried a number of times during remittance construction. Inspection of these pieces of furniture showed that they had high density, close packed foam cushions of a type similar to the particles observed in the surrounding area, which had been broken down by the repeated wet/dry cycle.

Scanning electron microscopy with energy dispersive xray spectroscopy (SEM-EDS) was used to identify the particles. The SEM showed an elevated concentration of iron and iron oxide in the impacted areas. The backscatter electron (BSE) image which correlates brightness in the image with atomic density, highlighted the iron particles that were embedded in the tile and the EDS spectrum confirms the PLM Image chemical composition of these higher density particles. See even more info at microvisionlabs.com.